Specifications

12.1
Basic operation
12
-15
Output signal monitor display
The indication of output signal is, like the monitor display of input signal, arranged like
above on the indicator of the panel or digital operator. When the output signal is ON ("L"
level) the lower half of the segment flashes and when the output signal is OFF ("H" level)
the upper half of the segment flashes.
• When the ALM1 signal is enabled (in case of "L", an alarm is output);
Display LED
number
Name of output
terminal
Presetting
1 CN153-38
/SKPOP1
2 CN5-17
/SKIP1
3 CN5-19
/SKIP2
4 CN5-97
ALM1
5 CN2-1
PGON
6 CN1-14,15
BK
7 CN1-17
RDY
3214567
Up: OFF ("H" level)
Down: ON ("L" level)
Number
EXAMPLE
3214567
the lower half
of Number 4
segment
flashes.