Specifications

How to use Digital Operation
12.1.8
Operation on the monitor mode
12
-14
Monitor display of input and output signal for sequence
The monitor display of the input/output signal for sequence is shown as following.
Input signal monitor display
The indication of input signal is arranged like above on the indicator of the SERVOPACK or
digital operator. The upper or lower side of the corresponding segment LED of the seven
segments flashes. When the input signal is ON ("L" level) the lower half of the segment
flashes and when the input signal is OFF ("H" level) the upper half of the segment flashes.
• When /EXIT1 signal is ON,
• When /EXT1 signal is OFF,
Display LED
number
Name of
terminal
Presetting
1 CN1-4
/EXT1
2 CN1-5
/EXT2
3 CN1-6
/EXT3
4 CN1-7
DEC
5 CN1-8
N-OT1
6 CN1-9
P-OT1
7 CN5-71
ESP0
8 CN5-73
SEQ0
8 3214567
Up: OFF ("H" level)
Down: ON ("L" level)
Number
EXAMPLE
83214567
the lower half
of the number 1
segment flashes.
83214567
the upper half of
the segment
number 1 flashes.