Specifications

10.2
MD components
10
-5
10.2 MD components
The following diagram shows the drive-related MD and the screen display types.
Schema of 840DI system
YS(840DI)
PLC (MCI board)
PLC application
NCK (PCU)
NCK application
CNC program analysis
Interpolation,
Acceleration/Deceleration
Position control
(CNC-side processing)
Backlash, Pitch errors
Tool replacement,
Data management
Machine data
PROFIBUS
I/F
(MCI board)
HMI (PCU)
ShopMill screen
Standard HMI (Maintenance screen)
HMI application
Customer HMI
(Exclusive customer screen
)
HMI application
Converter(MRXN)
Data bus Data bus Data bus Data bus
LatchSinal L atch signal Latch signal
Battery supply Battery supply Battery supply Battery supply
Soft ware
(0 0)
No parameter
Main soft ware
(F0**)
Main soft ware
(F***)
Main soft ware
(F***)
Main soft
ware
(F***)
Main soft
ware
(F0**)
Main soft
ware
(F0**)
Parameter
Cn000
1**,2**,4**,5**
Parameter
Pn000
1**,2**,3**
,4**,5**
Parameter
Pn000
1**,2**,3**,
4**,5**
Parameter
Pn000
1**,2**,
3**,4**,5**
The same as
the left
column
The same as
the left
column
General Channel
Axis
Drive parameter
DISPLAY
-MD
Digital
operator
General
Channel
MD 10000
19***
(Display screen is single)
MD 20000
29***
(Display screen is single)
Axis
MD 30000
38000
(The display screen has
a page(s) per *axis.)
SP
X axis
Y axis
Z axis
B axis
Spindle inverter
(MXN)
Feed X axis(SGDK) Feed Y axis Feed Z/B axis
<1-axis drive><1-axis drive><2-axis drive><1-axis drive>
Drive parameter
(Spindle)
MD 6000 to 8999
(Servo drive)
MD 3000 to 5999
SP
X axis
Y axis
Z axis
B axis
PRM number
MD
numbers are changed in
alignment
The content of setting is
also changed from decimal
number (drive side) to
hexadecimal number (NC
side).
W axis
W axis
Standard setting, Function Enabled/Disabled Mode setting, Compensation Value, Max/Min. Value
setting, and Setting of Gain or Integral Time Constant for the specific function
Content of parameter
Mode/Function setting
Gain
Integral time constant
Adjustment of the axis
behavior
Toque level
Feed W axis
Type:JUSP-JOP02A
Monitor PRM -> (Un0**)
Function PRM -> (Fn0**)
Monitor PRM -> (Un0**)
Function PRM -> (Fn0**)
Monitor PRM -> (Un0**)
Function PRM -> (Fn0**)
The same as
the left
column
The same as
the left
column
Monitor PRM -> (Un0**)
Function PRM -> (Fn0**)
Automatically set to the
first address number + 1
Specified with
even numbers
Indication/Axis-specific setting/
Content forwarding
Local bus
setting number
  ↓
  ↓  ↓
  ↓
"dr-#" indication
NC-side screen
configuration
NC-side screen
configuration
"X axis" indication is defined with MD1000.
The number in the " " is defined with MD20050.
Local bus setting RSW Local bus setting RSW Local bus setting RSW
Profibus setting is defined
through the hard ware