Product Description Deluxe Automatic Blood Pressure Monitor, Upper Arm Model
Model BP3400
Display LCD Digital Display Size: 84.1mm × 55.1mm (3.31” x 2.17”)
Measurement Method Oscillometric Method
Measurement Range
Pressure 0mmHg ~ 300mmHg
Pulse 30 to 180 Beats/Minute
Measurement Accuracy
Pressure ±3mmHg or ±2% of the reading above 200 mmHg
Pulse ±5%
Pressurization Automatic Pressurization
Memory 120 Memories in Two Groups with Date and Time
Function
Irregular Heartbeat Detection
WHO Classification Indicator
Last 3 Tests Average
Low Battery Detection
Automatic Power-Off
Power Source
4 AA batteries or Medical AC Adapter (DC6.0V, 600mA)
(recommended, not provided)
Battery Life Approximately 2 months at 3 tests per day
Unit Weight Approx. 382g (13.47 oz.) (excluding battery)
Unit Dimensions Approx. 148 x 100 x 56 mm (5.83” x 3.94” x 2.21”)(L x W x H(
Cuff Circumference
Approx. 135 (W) mm × 485 (L) mm
(Medium cuff: Fits arm circumference 22-36 cm)
Operating Environment
Temperature 10ºC~ 40ºC (50°F ~104°F)
Humidity 15% ~90%RH
Pressure Atmospheric Pressure
Storage Environment
Temperature -20ºC~ 55ºC (-4°F ~131°F)
Humidity 15% ~90%RH
Classification
Internal Powered Equipment,Type BF
, Cuff is the Applied Part
Specifications are subject to change without notice.
Maintenance
Specifications Specifications
Maintenance
1. Avoid dropping, slamming, or throwing the unit.
2. Avoid extreme temperatures. Do not expose unit directly under sunshine.
3. When cleaning the unit, use a soft fabric and lightly wipe with mild detergent.
Use a damp cloth to remove dirt and excess detergent.
4. Cuff Cleaning: Do not soak cuff in water! Apply a small amount of rubbing alcohol to a
soft cloth to clean cuff’s surface. Use a damp cloth (water-based) to wipe clean.
Allow cuff to dry naturally at room temperature.
5. Do not use petrol, thinners or similar solvents.
6. Remove batteries when not in operation for an extended period of time.
7. Do not disassemble product.
8. It is recommended the performance should be checked every 2 years.
9. Expected service life: Approximately three years at 10 tests per day.
International Standards:
AAMI / ANSI SP10:2002/(R) 2008 & 2002/A1:2003/(R)2008 & 2002/A2:2006/(R)2008
Manual, electronic, or automated sphygmomanometers
European Directive 93/42 EEC for Medical Products Act
EN 60601-1 Medical electrical equipment part 1: General requirements for safety
EN 60601-1-2 Medical electrical equipment part 1-2: General requirements for
safety- Collateral standard: Electromagnetic compatibility- Requirements and tests
EN 1060-1 Non-invasive sphygmomanometers - General requirements
EN 1060-3 Non-invasive sphygmomanometers - Supplementary requirements for
electromechanical blood pressure measuring systems.
EN 1060-4 Non-invasive sphygmomanometers - Test procedures to determine the overall
system accuracy of automated non-invasive sphygmomanometers.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product indicates that it should not be disposed with other
household waste at the end of its life. To prevent potential harm to the environment or to
human health, please separate this product from other types of wastes and recycle it
responsibly. When disposing this type of product, contact the retailer where product was
purchased or contact your local government office for details regarding how this item can
be disposed in an environmentally safe recycling center.
Business users should contact their supplier and check the terms and conditions of the
purchasing agreement. This product should not be mixed with other commercial wastes
for disposal. This product is free of hazardous materials.
SYS
DIA
PU
L
SE
M
SET
m
mH
g
m
mHg
/
min
S
TART
STOP
SYS
DIA
P
U
LSE
M
SET
m
m
H
g
mmH
g
/min
START
ST
O
P