Product Manual

Features
*One piece molded silicone rubber; small, light and comfortable.
*Clear mask allows a good view of nasal area.
*Low dead space results in low CO
2 build up.
*Dual 360 degree swivels at the mask attachment and at the standard 22mm tubing attachment point.
*Headgear with hook and loop fastener provide maximum versatility and movement.
Cleaning instructions
*Detach headgear from mask.
*Handwash gently with mild soap and warm water, rinse the mask and components thoroughly.
*Let mask and components air dry before reusing.
*Replace mask if there are cracks, tears or excessive di
scoloration.
NasalFit Deluxe EZ CPAP Masks
Small
Intended Use
The CPAP/VPAP Mask is intended to be used for patients who have been prescribed CPAP or VPAP therapy
and are under the specific direction of a physician. It is used in conjunction with continuous positive
airway pressure (CPAP/VPAP) devices in home, hospital and Institutional environments.
Figure 2
Identify headgear fastening
positions on the mask.
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Place the headgear over your
head and adjust both upper
headgear straps to a
comfortable tension.
Figure 8
Hook the plastic buckle A3
onto B3 and A4 onto B4 on
mask frame.
Figure 9
Adjust again both upper
headgear straps A1 & A2 to a
comfortable tension.
Figure 10
Figure 11
Adjust both lower headgear
straps A3 & A4 to a comfortable
tension.
Making sure the overhead strap
is in proper position to avoid
slipping down.
Contraindications
Caution
The use of bleach, chlorine, alcohol or aromatic-based solutions may cause harde
ning of the materials of
construction and reduce the life of the product.
This mask may not be suitable for patients with the following conditions: impaired cardiac sphincter function,
excessive reflux, impaired cough reflex and hiatal hernia. It should not be used if the patient is unresponsive,
obtunded, unable to remove the mask, or uncooperative.
Warnings
*This mask should only be used with CPAP systems recommended by your physician or respiratory therapist.
*Do not use this mask unless the CPAP or VPAP system is turned on and operating properly.
*Never block the mask's vent holes or exhalation port.
Note: CPAP systems are inten
ded to be used with special masks with ventholes in either the connectors or the
mask that allows continuous flow out of the mask. When the CPAP machine is turned on and functions properly,
new air from the CPAP machine flushes the exhaled air out through the mask's exhalation port. However, when
the CPAP machine is not operating, enough fresh air will not be provided through the mask and exhaled air
may be rebreathed. Rebreathing of exhaled air for longer than several minutes can in some circumstances
lead to suffocation.
*If oxygen is used with the CPAP system, the oxygen flow must be tur
ned off when the CPAP machine is not in
operation.
Note:When the CPAP device is not in operation and the oxygen flow is left on, oxygen delivered into the
ventilator tubing may accumulate within the CPAP machines enclosure and create a risk of fire.
Note: At a fixed flow rate of supplemental oxygen, the inhaled oxygen concentration will vary depending on the
pressure setting, patient pattern and leak rate.
*Do not smoke if oxygen is in use.
*Contact a health care professional if chest discomfort, shortness of breath, stomach distention, belching, or
severe headache ar
e experienced.
*Avoid eating or drinking three hours before using this mask to minimize the risk of vomiting during sleep.
*Do not use this mask if you are taking drugs that may cause vomiting.
Caution: At low CPAP pressures the flow though the exhalation port may be inadequate to clear all exhaled gas
from the tubing and some rebreathing may occur.
*Must only be used by persons who have received adequate training and instruction from qualified medical personnel
Figure 1
A1
A2
A3
A4
If headgear is included, follow assembling instruction below:
B1
B2
B3
B4
B1
A1
B2
A2
A3
B3
Place headgear with hook and loop
fastener side down on a flat surface,
detach 2 hook and loop fastener on
A1 & A2.
Pull the upper headgear strap A1
through the slot B1 on the mask,
making sure the hook and loop
fastener faces outward.
Fasten the hook and loop fastener. Fasten the hook and loop fastener.
* To remove the mask and headgear,
simply unbuckle both buckles from
the mask frame and pull the upper
head strap away from the head.
*To reuse the mask and headgear,
simply place upper headstrap over
head and hook up to both buckles.
Replacement Accessories
100NDEH NasalFit Deluxe EZ Replacement Headgear
100NDES-NH NasalFit Deluxe EZ CPAP Mask
Without Headgear, Small
100NDES-CUSHION NasalFit Deluxe EZ Replacement Cushion, Small
Pull the upper headgear strap A2
through the slot B2 on the mask,
making sure the hook and loop
fastener faces outward.
Drive Medical Design & Manufacturing
99 Seaview Blvd
Port Washington, NY 11050
Toll-Free 877-224-0946
www.drivemedical.com
Date of manufacture:
Caution
US federal law restricts this device to sale by or on the order of a physician.
2014-MM
100NDES
100NDES-NH

Summary of content (3 pages)