Installation Instructions

VENTILATION
Installers should provide adequate cross-ventilation during and for 24 hours after installation.
PRECAUTION
V.O.C. 0 grams/liter. Avoid eye contact. In case of eye contact, flush eye with clean water for fifteen minutes. If irritation persists, get medical
attention. Use with adequate ventilation. Keep out of reach of children.
FIRST AID
In case of eye contact, flush thoroughly with water for at least 15 minutes. SEEK IMMEDIATE MEDICAL ATTENTION. In case of skin contact, wash
affected areas with soap and water. If irritation persists, SEEK MEDICAL ATTENTION. Remove and wash all contaminated clothing. If inhalation
causes physical discomfort, remove to fresh air. If discomfort persists, SEEK MEDICAL ATTENTION.
INSTALLER RESPONSIBILITY
These directions are general guidelines for flooring installations. It is the responsibility of the installer to determine acceptability of subfloor
conditions. Installation must also be in accordance with flooring manufacturer’s recommendations. Only flooring that is approved for glue down
installations by the flooring manufacturer can be used with DriTac Eco-5500. Floors installed with DriTac Eco-5500 are not warranted against
damage caused by wet mopping, flooding, plumbing leaks or other extraordinary circumstances. For any installation not herein recommended,
contact DriTac Flooring Products before proceeding.
CLEAN UP
Wet adhesive can be removed with a damp cloth. Dry DriTac Eco-5500 can be removed with mineral spirits or a safe solvent. Hands and tools may be
cleaned with “waterless hand cleanser” available at hardware and auto supply stores.
WARRANTY
This product is warranted to be free of manufacturing defects. If a manufacturing defect is found within one year from the date of purchase,
such defective product shall be replaced. No warranty either expressed or implied is made regarding the performance of this product since
conditions under which these goods are transported, stored, used or applied are beyond our control. This warranty is made in lieu of all other
warranties either expressed or implied and the seller shall not be responsible for consequential, incidental, special or other damages no matter
what the cause.
60 Webro Road • Clifton, NJ 07012
www.DriTac.com
Vinyl Tile and Vinyl Plank
(over porous substrates)
DriTac trowel TR-8
1/16" x 1/16" x 1/16" square notched
Up to Approx. 200 sq. ft/gal spread rate
Vinyl Tile and Vinyl Plank
(over non-porous substrates)
Carpet Tile,
Fiberglass Backed Sheet Vinyl
1/16" x 1/32" x 1/32" U notched
Approx. 300 sq. ft/gal spread rate
Cork Tile/Cork/Rubber
/Foam Underlayment
(up to 1/4”)
DriTac trowel TR-3
3/32" x 3/32" x 3/32" V notched
120 sq. ft/gal spread rate
Cork Tile/Cork/Rubber
/Foam Underlayment
(greater than 1/4”)
DriTac trowel TR-5
1/8" x 1/8" x 1/8" square notched
80 sq. ft/gal spread rate
RECOMMENDED TROWELS
Multi-Ply
Engineered Plank
3/16" x 1/4" on 1/2" Centers
V notch
60 sf/gal spread rate
FIBERGLASS BACK SHEET VINYL INSTALLATIONS
The adhesive, floor covering, and area to receive flooring must be maintained at a temperature of 65°-95°F and at a relative humidity of 35%-65%
for 72 hours before, during, and after installation. Adhesives applied over non-porous substrates require extended drying time.
· Apply adhesive with a 1/16" x 1/32" x 1/32" u notched trowel, depending on surface and strength of bond desired. It is the installer's
responsibility to apply the proper amount of adhesive for the job condition.
· Allow adhesive to dry to the point where it will not transfer to the fingers when pressed.
· Lay flooring according to manufacturer’s recommendations.
· For permanent installations, (over porous substrates only) install fiberglass backed sheet vinyl into the wet adhesive
· Complete the job by using th e "Broom Method" or installer's choice for removing air pockets.
NOTE: Restrict heavy traffic on floor for 48 hours after installation.
Application Note: If rolling of the adhesive is preferable, please inquire about DriTac Eco-5200 Pressure Sensitive Flooring Adhesive.
CORK TILE INSTALLATIONS
· Check with cork manufacturer for moisture testing, acclimation and other special installation instructions.
· Area to receive flooring should always acclimate to "live in" temperature and humidity conditions.
· When installing cork flooring using DriTac Eco-5500, the adhesive must be used as a contact adhesive. Begin by spreading DriTac
Eco-5500 on the sub floor using the appropriate trowel and allow the adhesive to completely dry. Ensuring the adhesive is thoroughly dry will
help prevent moisture being transferred to the tile. Drying time will vary with the temperature and humidity conditions. After the adhesive has
thoroughly dried on the sub floor apply a thin coat of adhesive to the back of the cork tiles using a paint bush or paint roller. Allow adhesive on
the back of the cork to flash for approximately 15 minutes before installing the tiles. Roll the flooring during and immediately after installation.
Allow for recommended expansion space.
1) When installing cork tiles up to 1/4" in thickness use DriTac trowel TR-3, 3/32" x 3/32" x 3/32" v notch. Spread rate 120 square feet per gallon.
2) When installing cork tiles greater that 1/4" in thickness use DriTac trowel TR-5, 1/8" x 1/8" x 1/8" U notch. Spread rate 80 square feet per gallon.
CORK/RUBBER/FOAM UNDERLAYMENT INSTALLATIONS
· Unroll underlayment and cut sections approximately 2" wide off roll. Vertically adhere this isolation barrier around the perimeter of the entire
floor with DriTac Eco-5500.
· Never mechanically fasten the isolation barrier with screws, nails or staples as this will severely diminish the acoustical values of the barrier.
· Cut underlayment to length and lay loosely over the area to be installed. Both ends of the roll must curl down towards the subfloor, if they curl
up, turn the underlayment over. Butt the underlayment directly against the isolation barrier already installed.
· Pull the loose laid material back at least half the length of the roll. Using a 1/8" x 1.8" x 1/8” square-notched trowel for underlayment greater
than ¼", or a 3/32" x 3/32" x 3/32" v-notched trowel for ¼" thick underlayment or less, apply DriTac adhesive to the subfloor. Allow DriTac Eco-
5500 to flash for 30-40 minutes prior to placing underlayment into adhesive. Upon placing underlayment into the adhesive, roll both ways with
a 100 lb roller. Repeat the installation for the other half of the subfloor, insuring all joints are butted together tightly.
· Allow adhesive to set prior to proceeding to flooring installation. It is highly recommended to allow at least 18 hours prior to
installation of the flooring.
Tel: (800) 394-9310 • Fax: (973) 614-9099
Email: Info@DriTac.com