Seed Meter Test Process (using CAL TEST function)
This procedure is used prior to eld operation. These steps will verify the DrillMaster
and your seed meter dispenses the correct number of seeds.
Preparation
1. Fill drill with seed.
2. Position catch container under each seed tube.
Enter Calibration Mode (switch controller to hold and press the “CAL” button until the red light is
solid)
1. Turn Rotary Position Switch to “Cal Test”, “Off” appears in the display, press “+” to activate the
Calibration Test mode .150 appears in the display to dispense a 150 seed sample. To set sample size
see singulated seed calibration.
2. Turn rotary position switch to “Test Speed”.
3. Use “+” to enter normal operating speed.
4. Turn rotary position switch back to “Cal Test”.
5. Switch from the hold to the run position and turn all section on. The “Cal Test” will begin. The display
will count up the measured sample size and automatically turn off at one (1) lb.
6. Count the seeds to verify proper operation and calibration.
7. Press and hold “CAL” until red light is off to exit calibration.
If the proper number of seeds is not dispensed:
1. Check “Meter Cal”.
2. Is the meter drive shaft speed sensor properly aimed at 60 tooth target (1/16 - 1/8” clearance)
3. Is drive ratio a 19 tooth driver to 20 tooth driven from drive shaft to seed meter.
4. Is meter and vacuum level adjusted properly.