User Manual
User Manual
RANGE HOOD | ECLIPSE
7
Fault
Cause
Solution
Light on, but motor does not
work
The leaf blocked
Get rid of the blocking
The capacitor damaged
Replace capacitor
The motor jammed
bearing damaged
Replace motor
The internal with of motor
off or a bad smell from
the motor
Replace motor
Light does not work, motor
does not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord looses
Connect the wires as per
the electric diagram
Oil leakage
One way valve and the air
ventilation entrance are not
tightly sealed
Take down the one way
valve and seal with glue
Leakage from the
connection of U-shaped
section and cover
Take U-shaped section
down and seal with soap or
pain
Shake of the body
The leaf damaged and
causes shaking
Replace the leaf
The motor is not tightly
hanged
Lock the motor tightly
The body is not tightly
hanged
Fixed the body tightly
Insufficient suction
The body is not tightly
hanged
Readjust the distance
Too much ventilation from
open doors or windows
Choose a new place and
resemble the machine
The machine inclines
The fixing screw not tight
enough
Tighten the hanging screw
and make it horizontal
The hanging screw not
tight enough
Tighten the hanging screw
and make it horizonta.