Below are the steps required to install the Command Hub in 2800i and 3500i dehumidifiers.
Find these instructions and more information on the Command Hub at
DehuCommandHub.LegendBrandsRestoration.com
Step 1
Unplug or disconnect power to the dehumidifier.
Using a #2 Philips screwdriver, remove the 4 mounting
screws set aside and save to secure the Command Hub.
Step 2
Lift out the old i-Series controller and remove the 4 cables
from the back 2 temp sensors and 1 data cable.
Step 2a
Use a 1/16" drill bit to drill a pilot hole roughly 1/4" above
the air inlet hole (see photo). IMPORTANT: Do not drill
more than 1/4" past the plastic to prevent drilling into the
filter behind the inlet.
Step 2b
Remove and discard the plastic stud that is connected to
the sensor included with this kit.