Installation Guide

Installation steps
6CHARISMA manual Ver 3 Rev 4 10/2016
Fig 1
Fig 2
W
W
W
GUIDE RAIL (#01)
W = FINISHED OPENING -1/16”
Metal File
1. Measure the finished opening width at
the top, middle and bottom. This distance is
marked as “W”.
See Fig 1 for details
2. The Guide Rail (#01) and the Bottom Rail (#02) have
been precut for your model size width of 48” or 60”.
If your finished opening width is less than 48” or 60”, you
will need to cut the Guide Rail (01) and the Bottom Rail
(02) to “W” (W = finished opening -1/16”).
>The Guide Rail (#01) can be cut from either end. (Fig 2)
>The Bottom Rail (#02) must be cut equally from both
ends. (Fig 3) so that the center guide holes stay centered.
You can use a miter saw or a hack saw. Use a metal file to
file down any burrs that occur to prevent scratches to the
wall.
See Fig 2 for details
NOTE: This unit does not allow for out-of-plumb
wall conditions.