4.  Slip the cut U-channel 2 (bottom profile) (29) and 
U-channel 1 (wall profile) (09) onto the Stationary 
glass (11) in the shown locations.  
With  the  door  open,  place  the  Stationary  glass  on 
the  half  wall  ledge  opposite  of  door.  Adjust  the 
Stationary  glass  and  U-channel  1  (wall  profile) 
against the wall to compensate for any out of plumb 
conditions ensuring that the Stationary glass is level 
vertically and U-channel 1 is flush with the wall. 
NOTE:  The  exposed  vertical  glass  edge  must  be 
flush with the finished half wall’s door side face. 
Mark  the  U-channel  2  (bottom  profile)  end 
opposite  of  the wall  at  the exposed  vertical  glass 
edge. 
Remove  the  U-channel  2  (bottom  profile).  Leave 
the  U-channel  1  (wall  profile)  on  the  Stationary 
glass. Set the Stationary glass aside. 
Cut the U-channel 2 (bottom profile) at the mark. 
Slip  the  U-channel  2 (bottom  profile)  back  onto 
the Stationary glass. 
See Fig. 5 for details. 
wall
inside
inside
Stationary
glass
U-channel 2
U-channel 1
wall
inside
 Fig. 5 
1 
3 
5 
2 
4 
6 
H (+) 1"
b) 