Installation Guide
© DreamLine
 All Rights Reserved
© DreamLine
 All Rights Reserved
Installation steps for 6” hinge panel with Hinge Panel Glass Bracket
10
UNIDOOR-X (STYLE M) manual Ver 2 Rev 1 02/2019
©2019 DreamLine. All Rights Reserved
!
NOTE:  Refer to the 
enclosure panel 
manual for the 
correct dimensions 
for enclosure 
installations
Plumb line
Out-of-plumb 
at the bottom
<Less than 90°
A
Plumb line
**If the wall is 
out-of-plumb at the 
bottom, measure that 
dimension (A) and add
it to the length of the 
U-channel (1/4” max):
Finished cut length=
Glass Width + 3/16” 
+ dimension A 
Vertical 
U-channel
Hinge Panel
Glass Bracket
1-9/16”
69-7/16”
6”
Bottom 
U-channel**
Fig 2
Carpenter’s
Square
Model 
height 
of 72”
Fig 1
1. Draw a line on the threshold and up the 
wall to represent the outside edge of the 
U-channels. Make sure the line is parallel to 
the front edge of the threshold. (Fig 1)
2. Use a hacksaw or a miter saw: 
Cut the Vertical U-channel to 69-7/16”. 
Cut the Bottom U-channel** to 6”. (Fig 2) 