User manual

14.0 MAINTENANCE
38 R699820 - Yunzi Series User Manual
Light-source Lamp and Lamp Usage Time
The life of light-source lamps used for this unit is about 4000 hours when running this unit in low lamp mode.
When the lamp power is set to Low, the lamp life is approximately 4000 hours. This average lamp life is not
guaranteed and may not reach 4000 hours depending on the operating conditions.
Deterioration progresses rapidly when the remaining lamp usage time is short. Get ready or replace with a new
lamp when the accumulated usage time exceeds 4000 hours. Depending on the operating conditions, the lamp
may have to be exchanged earlier.
If the image is dark or if the color tone is abnormal, replace the lamp as soon as possible.
•You can also check the accumulated hours of usage. Please refer to Lamp Time in the Information menu.
When the lamp usage time exceeds 2900 hours
The Lamp replacement message will be displayed on the screen the next three projection starts.
Press the [BACK] button to clear the display.
Procedure for Lamp Replacement
During the lamp replacement process, you may have access to sensitive parts of the projector.
Loosen the screw on the lamp trap at the rear of this unit.
Open the lamp Cover and loosen the 2 screws on the lamp unit to release it.
Pull out the lamp unit using the handle.
Insert the new lamp unit until it is firmly in place.
Tighten the screws of the lamp unit.
Attach the lamp cover and fasten the lamp trap screw.
Resetting Lamp Time
After installing a new lamp, reset the lamp time using the OSD menu.
ABOUT LAMP REPLACEMENT
If this unit is installed in a constricted place, attempting to replace the lamp in that place may cause injury. Move this
unit to a place large enough to perform work.
Use only genuine replacement parts for the lamp unit. Otherwise, malfunction may occur. Also, never attempt to re-
use an old lamp unit. This may cause marked performance deterioration or lamp blowout, thus leading to unit
malfunction. Broken pieces of the lamp outside this unit may also cause injuries during lamp unit exchange.
Do not replace the lamp immediately after this unit has been used. The temperature of the lamp is still high and this
may cause a burn. Allow a cooling period of 1 hour or more before replacement.
Before replacing the lamp unit, pull out the power plug from the outlet and wait until the STANDBY/ON led is still light
red. Replacing a lamp with the plug connected to the outlet may cause injuries or electric shocks.