Installation Instructions

06490053001 Iss B
0205
Customer Service Tel: +44 (0) 845 130 5522
Technical Helpline Tel: +44 (0) 845 130 7722
Room thermostats
Make Model
Drayton RTS 1 & 2 N L 3
Drayton RTS 4, 5, 9 & 10
N
L 132
2311 tatsigiDnotyarD
ACL Lifestyle PT271/371 N L 132
ACL Lifestyle TS 142 E 4 1 2
ACL Lifestyle TA 350 5 132
Drayton Digistat (old version) 4 123
Drayton RT & RTE 4 123
Danfoss Randall TP1 E N L 1 2
2315 & 4 ,3 ,2PT .1TRlladnaR ssofnaD
Danfoss Randall RD3, RD3A 4 1 2
Danfoss Randall RTC, RTM, RSR E N 312
213N405RlladnaR ssofnaD
Honeywell 6060, 6061, 6063 2 134
CBA002TCllewyenoH
Horstman HRT 1 E 4 1 2
Landis & Gyr RAD 1 E 123
Potterton PRT 1 N L H
Potterton PRT 2 & 100 ST N TL H
Potterton PRT 100 DT N TL H C
Sunvic TLX 2259 E N L 1 2
Sunvic TLX 2356 E 312
Sopac TA 350 E 132
Sopac TA 351 E 4 132
Switchmaster SRT 2 5 132
Tower SS E 4 1 2
Earth
Neutral
Live
Common
Demand
Satisfied
Wiring (schematic)
Note: It is essential to make a neutral connection to terminal N.
Note: Link between terminals L and 1 if mains voltage is
required on the thermostat switch.
Information
The RTS room thermostat replaces earlier models of both
ACL and Drayton room thermostats subject to a maximum
load of 2(1)A 230V ac. The wiring conversion between
these models is:
ACL ACL Drayton RTS RTS
TS142 TA350 Roomstat 1,2 4, 9,
RT (E) & 3 & 10
Live supply 1 1 L L
Neutral
4 4 N N
(accelerator heater)
Call for heat 2 3 2 3 3
Heating satisfied
2 3 2
(call for cooling)
Volt free
1 1
switch common
Earth connection E 5
Conforms to the essential requirements of the following
directives:
Relevant EC Directives
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic
Compatibility Directive
2011/65/EU RoHS Directive
Applied Standards
EN60730-1, EN60730-2-9
N L 1 2 3
N
230V AC 50HZ
fused 3A
L
Call for
heat
RTS1, RTS2 and RTS3
N L 1 2 3
N
230V AC 50HZ
fused 3A
L
Call for
heat
RTS4, RTS9 and RTS10
COM
Heating satisfied o
r
call for cooling
Energy Class: IV = 2%
(According to EU
811/2013, 812/2013,
813/2013, 814/2013)