Operation Manual

VigorSwitch P2121User’s Guide
6
Blinking The system is sending or receiving data through the
port.
Port 1 ~ 8
Off The port is disconnected or the link is failed.
On (Green) The device is connected with 1000Mbps.
On (Amber) The device is connected with 10/100Mbps.
Blinking The system is sending or receiving data through the
port.
Combo for
Port 9 ~ 12
(RJ 45
LNK/ACT)
Off The port is disconnected or the link is failed.
On (Green) The device is connected with 1000Mbps.
On (Amber) The device is connected with 10/100Mbps.
Blinking The system is sending or receiving data through the
port.
SFP LNK/ACT
Off
The port is disconnected or the link is failed.
C
C
o
o
n
n
n
n
e
e
c
c
t
t
o
o
r
r
E
E
x
x
p
p
l
l
a
a
n
n
a
a
t
t
i
i
o
o
n
n
Interface Description
Console
Used to perform telnet command control.
RST
Factory reset button.
Press it to reboot the system. (<5 seconds) The
PoE/Alert and SYS LEDs will blink too.
Press it to reset the system with factory default
settings. (5~20 seconds)
The PoE/Alert and SYS LEDs will be off if RST button is
pressed between 5 seconds and 10 seconds.
RJ 45 LNK/ACT Port 1 ~ 8
PoE for Port 1 ~ 8
Port 1 to Port 8 can be used for Ethernet connection
and PoE connection, depending on the device
connected
.
SFP LNK/ACT Port 9 ~ 12
Port 9 to Port 12 are used for fiber connection.
Power inlet for AC input (100~240V/AC, 50/60Hz).
Note:
Power Output –
IEEE 802.3af Max. 15.4W Output Supported
IEEE 802.3at Max. 30W Output Supported
PoE Power Budget--
140 Watts