This page is used to configure device check of PoE PD devices. It can be applied to PoE PD
devices connected directly, check ping echo status, and forcely reboot the device when
meeting the preset health condition.
The configuration result for each port will be displayed on the table listed on the lower side
of this web page.
Available settings are explained as follows:
Item Description
Port Use the drop down list to select the port (GE1 to GE24) or
ports for device check.
Enable Disable – No PoE function for the selected GE port.
Enable – PoE function will be enabled for the selected GE port.
Ping IP Address Enter the IP address of the PoE device for check.
Interval Time (sec.) The ping check will be performed every 10, 30, 60 or 120
seconds for the selected port (PoE device).
Retry Time The system will perform the ping check the selected port (PoE
device) for 1, 3 or 5 times.
Failure Action Specify the action performed for PoE device when there is no
number of retry time of echo from given IP address.
Power Cycle – Forcely reboot the device by cycling the power
given to PoE device.
Power Off – The PoE divice will be powered off.
Nothing – Log this event only, no action is taken on PoE
device.
Apply Save the settings or changes to the switch.