LLDP is a one-way protocol; there are no request/response sequences. Information is
advertised by stations implementing the transmit function, and is received and processed by
stations implementing the receive function. The LLDP category contains LLDP and
LLDP-MED pages.
3
3
.
.
8
8
.
.
1
1
.
.
1
1
P
P
r
r
o
o
p
p
e
e
r
r
t
t
y
y
Function name:
Management>>LLDP>>Property
Function description:
Parameter description:
State
Check it to enable LLDP protocol on this switch.
LLDP Handling
It is enabled when State is unchecked.
Select LLDP PDU handling action to be filtered,
bridging or flooded when LLDP is globally disabled.
TLV Advertise Interval
Select the interval at which frames are transmitted. The
default is 30 seconds, and the valid range is
5–32768seconds.
Hold Multiplier
Select the multiplier on the transmit interval to assign to
TTL (range 2–10, default = 4).
Reinitializing Delay
Select the delay before a re-initialization (range 1–10
seconds, default = 2).
Transmit Delay
Select the delay after an LLDP frame is sent (range
1–8192 seconds, default = 3).
Apply