Installation guide

VigorAccess Installation Guide
34
alarm relay connector also provides one set of contacts for audible alarms and one set for
visual alarms. The maximum contact rating is 30VDC, 2A 125VDC, 0.5A.
Pin8 Pin1
The table below lists the pin assignments for backplane connector RJ45, the alarm relay
connector.
Pin Signal Description
1 NC1 (NORMAL CLOSE CONTACT GROUP1)
2 COM1 (COMMON CONTACT GROUP1)
3 NO1 (NORMAL OPEN CONTACT GROUP1)
4 NOT USED
5 NOT USED
6 NC2 (NORMAL CLOSE CONTACT GROUP2)
7 COM2 (COMMON CONTACT GROUP2)
8 NO2 (NORMAL OPEN CONTACT GROUP2)
A
A
.
.
3
3
R
R
S
S
2
2
3
3
2
2
C
C
o
o
n
n
n
n
e
e
c
c
t
t
o
o
r
r
The RJ45 connection jet is used for CLI commands for system configurations and
controlling functions in the VigorAccess. The jet is used for initialization of the
VigorAccess during the preliminary installation. The “management cable”, as shown in
Figure 1-15, converts the RJ45 to the RS232 interface. The RJ45 jet connects to a console
interface in the VigorAccess, while the RS232 DB9 connecting to a console port on the
computer.
The default setting of the console port is “baud rate 9600, no parity, and 8 bit with 1
stop bit (N81)”.
The pin-out for this connector is shown below:
RJ45 DB9 (Female) Signal
No connection 1 CD
3 2 TD
6 3 RD
7 4 DTR