scroll to choice one for your sampler type. By default, The
value is “None”.
Sampling Rate –Configured sampling rate on the ports.
Max Hdr Size – Configured size of the header of the
sampled frame.
Counter Sampling Counter sampling performs periodic, time-based sampling
or polling of counters associated with an interface enabled
for sFlow.Attribute associated with counter sampling is
polling interval.
Polling Interval - Configured polling interval for the counter
sampling.
To edit the configuration for each sFlow Ports, click the button to open the following
page.
Parameters description:
sFlow Ports This is the port number on which sFlow can be configured.
sFlow Instance Multiple instances of sFlow can be supported on the port.
Currently we support one sFlow instance on each port due
to hardware limitation.
Sampler Type Sampler type on the port can be one of the following types:
None, RX,TX, ALL.If type is "none" then the sampling rate
is 0 and no other value is accepted.The default value is
"none".
Sampling Rate Determines the rate at which samples must be taken on the
ports. If sampling rate is configured as 'N',1/N frames is
sampled.
The sampling rate ranges from 0 to 4095.
Default value is "0" meaning sampling is disabled on the
port.
If receiver time_out is 0sec, this sFlow configuration is
disabled operationally.