4.5 Shut Down Procedure
1. Place the power switch (2) to the OFF (0) position or if used
set the thermostat to the lowest setting. By placing
the power switch in the OFF (0) position or setting the thermostat to the lowest setting, the flame will go out, but
the fan continues to spin for approximately 90 seconds cooling the combustion chamber.
CAUTION
Surfaces and pieces may be hot.
2.
Remove the exhaust stack and heater duct. (Ensure items are cool before removing).
3. Repack the exhaust stack inside the heat outlet fabric cover.
4. Repack operator’s manual and remote thermostat / CO detector into the accessories bag.
5. Return the accessory bag to its compartment in the base of the heater.
6. Repack heater ducts into transport bag.
7. Replace protective fabric covers on each end of the heater.
4.6 Filling the Fuel Tank
WARNING!
DO NOT USE GASOLINE
. USING ANY UNAPPROVED FUELS FOR THE HEATER COULD
RESULT IN DAMAGE TO THE HEATER, VOID WARRANTY AND / OR PERSONAL INJURY.
Ensure the power switch is in the OFF (0) position. It is recommended to allow 5 minutes
for the D-1000B heater to cool
before refueling.
1. Unplug the power cord from the power supply.
2. Unscrew the fuel cap and refuel the heater. (Use Diesel fuel).
3. Reinstall the fuel cap. Clean any spills that may have occurred.
4. Reconnect the heater to the power supply; resume heater usage by placing the power switch (2) to the ON (II)
position if using the remote thermostat or to the ON (I) position if not using the remote thermostat.