Operating instructions
Access Instructions by Draper page 3 of 4
Mounting hardware
supplied by others
Case Dimensions
4
3
/
4
"
2
1
/
8
"
1
3
/
16
"
Engagement bracket (one on each end
of the bottom access panel) clicks into
place with the ball detent on each endcap
*These wiring diagrams are for Access screens with motor on audience left
(standard), and fabric unrolling from the back of the roller (standard).
www
.draperinc.com
(765) 987-799
9
L
Access L
Series E 7"
Series V Varies
Mounting brackets slide
left and right as needed.
Series E or M
Series V
9"
8"
7"
6
5
/8"
2
1
/8"
slot
11
/16"
1"
11
/
16
"
6
5
/8"
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
Wiring Diagrams—110-120V Motor and Quiet Motor
Wiring Diagrams—110-120V Motor and Quiet Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
To 110-120V Line
Multiple Low Voltage Controls
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
To 110-120V Line
Wall Switch,
RF or IR
Receiver,
or integrated
control system
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
Data Cable
Data
Cables
Limit Adjustments (Built-in Low Voltage Motors)
Please Note: Screen limits are factory set for optimum
performance of the screen. A procedure is outlined below for
minor tweaks, but any adjustment of these limits may negatively
affect the flatness of the screen surface and could also void the
warranty. Please check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when
new adjustment is being tested. Screen may be severely damaged
if viewing surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before
adjusting limit switches.
Please note: When ordering a motor with built-in Low Voltage
Controller, if the case ships separate from the "guts," the case
includes the 25' cable and special low voltage switch.
1 Connect the ILT switch to the motor via the terminal blocks, or via
the modular port using four conductor modular cable. When using
modular cable, the cable connectors MUST NOT be crimped in
reverse, as with standard telephone cable. (For a Dry Contacts Wir-
ing Diagram, see page 4.)
2 Set the slide switch to the lower position. Press and hold the DOWN
button on the switch to move the viewing surface to the desired
lower limit. If the screen moves in the opposite direction, release the
DOWN button and press and hold down the STOP button for four
seconds. This will reverse the operation of the UP and DOWN
switches.
3 Move slider switch into center position.Wait a couple of seconds.
Please Note: If you move the slider switch from down to up in one
motion it sets the two limits in the same position.
4 Set the slide switch to the higher position. Move the viewing surface to
desired upper limit by pressing and holding the UP button on wall switch.
5 Return the slide switch to the center position to return to normal
operation.
6 To set the viewing surface to an alternate format position, move the
viewing surface to the desired position and press the STOP button.
Press and hold the STOP button for at least three seconds to record
the position.
Please Note: Pressing and releasing the UP button on the switch
will move the screen to its upper limit. Pressing and releasing the
DOWN button will move the screen to its lower limit.
While the motor is in motion, pressing the STOP button for less than
two seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the
viewing surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or
in motion, for at least three seconds will record a new
alternate format
position.
SSTTOOPP
To
Motor
Back View
SW1 SW2
FUNCTION
ON
ON
OFF
OFF
OFF OFF
Set LOWER limit
Set UPPER limit
RecordPosition/
Normal Operation
OFF
12
U
p
D
o
w
n
G
r
o
u
n
d
+
5V
Please Note: Do not wire motors in parallel.
SSTTOOPP
To
Motor
Back View
SW1 SW2
FUNCTION
ON
ON
OFF
OFF
OFF OFF
Set LOWER limit
Set UPPER limit
RecordPosition/
Normal Operation
OFF
12
U
p
D
o
w
n
G
r
o
u
n
d
+
5V
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.