Operating instructions

Access Instructions by Draper page 3 of 4
Mount ing
hard ware
supplied by
others
Case Dimensions
4
3
/
4
"
2
1
/
8
"
1
3
/
16
"
Engagement bracket (one on each end
of the bottom access panel) clicks into
place with the ball detent on each endcap
*These wiring diagrams are for Access screens with motor on audience left
(standard), and fabric unrolling from the back of the roller (standard).
www.draperinc.com
(765) 987-799
9
L
Access L
Series E 7"
Series V Varies
Mounting brackets slide
left and right as needed.
Series E or M
Series V
9"
8"
7"
6
5
/8"
2
1
/8"
slot
11
/16"
1"
11
/16"
6
5
/8"
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
Wiring Diagrams—110-120V Motor and Quiet Motor
Wiring Diagrams—110-120V Motor and Quiet Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
To 110-120V Line
Multiple Low Voltage Controls
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
To 110-120V Line
Wall Switch,
RF or IR
Receiver,
or integrated
control system
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
Data Cable
Data
Cables
Limit Adjustments (Built-in Low Voltage Motors)
Connect the ILT switch to the motor via the terminal blocks, or
via the modular port using four conductor modular cable. When
using modular cable, the cable connectors MUST NOT be
crimped in reverse, as with standard telephone cable.
Set the slide switch to the lower position. Press and hold the
DOWN button on the switch to move the viewing surface to
the desired lower limit. If the screen moves in the opposite
direction, release the DOWN button and depress the STOP
button. This will reverse the operation of the UP and DOWN
switches.
Set the slide switch to the higher position. Move the viewing
surface to the desired upper limit by pressing and holding the
UP button on the wall switch.
Return the slide switch to the center position to return to nor-
mal operation.
To set the viewing surface to an alternate format position, move
the viewing surface to the desired position and press the STOP
button. Press and hold the STOP button for at least three
seconds to record the position.
Please Note: Pressing and releasing the UP button on the
switch will move the screen to its upper limit. Pressing and releas-
ing the DOWN button will move the screen to its lower limit.
While the motor is in motion, pressing the STOP button for less
than two seconds will stop the viewing surface at its present
position.
Once the motor is stopped, pressing the STOP button will
move the viewing surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at
rest or in motion, for at least three seconds will record a new
alternate format position.
S
S
T
T
O
O
P
P
To Motor
with
Built-In
Low Voltage
Slide
Switch
Back View
U
p
D
o
w
n
C
o
m
m
o
n
+
5V
DC
To Motor
with
Built-In
Low Voltage
POSITION
FUNCTION
DOWN
UP
CENTER
Set LOWER limit
Set UPPER limit
Normal Operation
STOP