Operating instructions

Scissor Lift SL by Draper page 5 of 5
www
.draperinc.com (765) 987-7999
Wiring Schematic
N
U C D
Dashed wiring by electrician
115V ac,
Supply
Attached to lower pan
WH
BKBK
WH
GN
WH
WH
Encoder
RD
BK
WH
RD
BN
RD
WH
BK
YL
YL/GN
RD
BK
BK
OR
Up
Limit
Switch
NC
NC
RD
BN
NC
Down
Limit
Switch
2 Cond. Cable
Delay Switch
(on position)
RD
BK
BK
OR
BK
BK
RD
BL
YL/GN
BK
Motor
Up
Down
BK
BK
BK
WH
OR
RD
BK
BK
WH
OR
RD
AC
AC
COM
N.O.
N.C.
BK
WH
RD
OR
Optional Delay Assembly
115V ac, 7A 60 Hz Outlet
Run Cap
45 MFD
BK RDWH
WH
RD
BACK OF DATA CABLE
SPLITTER BOARD
FRONT OF DATA CABLE
SPLITTER BOARD
KEY
WALL
RP/RQ
RP/RQ
LVT
RD
BKBK
OR
Up
Limit
Switch
NC
NC
BK
Jumper*
ALTERNATE ‘UP’ LIMIT SWITCH WIRING
NOTE: This CANNOT be
used when lift is installed in
Environmental Air Space Housing
and Optional Ceiling Closure
*Black (BK) Jumper wire is
located in the plastic sleeve
with these instructions.
DOWN
Limit
Switch
DOWN
ROTATE
TO
ADJUST
ROTATE
TO
ADJUST
Adjusting FULLY DOWN position
Limit switches for the Scissor Lift SL are preset at the factory.
The DOWN limit switch is set for the fully down (maintenance) position for
the size lift you have ordered. The limit switch assembly is located inside
the lift and behind the Lifting Cable Drum.
The Down limit switche shown in the drawing are for setting the "Fully
Down" position. This can be adjusted manually by loosening or tightening
the screw to increase or reduce the travel.
Caution: The maintenance/service factory limit setting must
not be adjusted to a lower position than the preset factory limit
setting. In addition, Draper does not recommend setting show
position at the maintenance/service position.