Operating instructions

28881 Rev G 6 01-02
NOVUS REAR DIRECT VENT
1. APPLIANCE LOCATIONS AND SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance
may be located in a room. The NOVUS Series may be
installed directly on the floor or raised on a hearth.
These appliances are certified for installation in a
bedroom, bed/sitting room, or in mobile homes in the
U.S. and Canada.
WARNING!
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draper-
ies.
2. CLEARANCES
a. For all appliances:
Top of stand-offs 0
Floor 0
Back of appliance 1/2
Side of appliance 1/2
Top of drywall flange to ceiling 30
b. Minimum Venting Clearances (See Fig. 2)
Horizontal runs off back of appliance to wall shield:
1 sides and bottom of vent (see Fig. 2 for top
of vent)
Horizontal runs inside a wall (Heat Shields must
be installed):
3 air space on top of vent
1 sides and bottom of vent
Vertical runs:
1 air space around vent
Figure 1 - Appliance Locations
Figure 2
Rear Vented Appliances Venting Clearances
CAUTION:
Do not expose the appliance to the elements (such
as rain, etc.)
ledoMA
33CRNG"8/7-83
63CRNG"8/7-14
63HRNG"8/7-14
* Dimensions represent minimum space required for
a centered corner installation. Actual requirements
will vary with individual construction. Depending on
individual construction and appliance location,
additional space may be needed to meet required
vent and cap clearances.
ledoMA
33CRNG"8/1-9
63CRNG"7
63HRNG"8/1-9
Framing to wall
must be
above the
appliance stand-
offs.