Datasheet
MRC_eco
Version 1.1 │11.01.2011
page 1 of 3
MRC eco
www.draka.com/communications koeln.info@draka.com
Application
The radio-frequency cables described in this chapter are used in transmitter and receiver installations in radio communications as well as in
the entire field of commercial radio-frequency technology and electronics.
Standards
EN 50117-1, IEC 61196-1
Construction
MRC 195
ECO
(0.94/2.79)
MRC 200
ECO
(1.12/2.95)
MRC 240
ECO
(1.42/3.81)
MRC 400
ECO
(2.74/7.24)
MRC 600
ECO
(4.47/11.56)
Inner conductor
Copper wire, bare
0.94 mm ± 0.01
Copper wire, bare
1.12 mm ± 0.01
Copper wire, bare
1.42 mm ± 0.01
CCA*
2.74 mm ± 0.03
CCA*
4.47 mm ± 0.03
Insulation
Foam-PE 2.79 mm ± 0.1 2.95 mm ± 0.1 3.81 mm ± 0.1 7.24 mm ± 0.1 11.56 mm ± 0.1
Outer conductor
Al-PET Foil, bonded to the dielectric + Aluminium braid
Sheath
PE, black
UV stabilized
4.95 mm ± 0.3
4.95 mm ± 0.3 6.1 mm ± 0.3 10.3 mm ± 0.3 15.0 mm ± 0.3
Printing
DRAKA
MRC 195 ECO
+ batch number
+ meter marking
DRAKA
MRC 200 ECO
+ batch number
+ meter marking
DRAKA
MRC 240 ECO
+ batch number
+ meter marking
DRAKA
MRC 400 ECO
+ batch number
+ meter marking
DRAKA
MRC 600 ECO
+ batch number
+ meter marking
*CCA - Copper Clad Aluminium
Mechanical properties
Minimum bending radius without load 5 x D ( D= outer diameter )
with load 10 x D ( D= outer diameter )
Temperature range during operation - 40° C to + 85° C
during installation - 15° C to + 55° C
Corrosivity acc. to IEC 60754-1/2
50Ω Cables for indoor/outdoor applications