Specifications
Fig. DUw 3
ASME: A 112.18.2
CSA: B 125.2
*PATENT PENDING,
US & CANADA
EUIPO 006316741-0001*
Installer must verify all rough-in dimensions prior to installation and consult local
and national codes. Adherence and compliance to local and national codes are the
responsibility of the installer.
Data Sheets are subject to change without notice. For latest revision please
contact Drains Unlimited, Inc.
SELECTED WALL TILE OR STONE
5
8
" CEMENTITIOUS BOARD
WATERPROOF MEMBRANE
TILE DRAIN GRATE
SCHEDULE DUW(R)
DRAIN BODY
SELECTED FLOOR TILE OR
STONE
WATERPROOF MEMBRANE TO
RUN UP SHOWER WALLS TO
CEILING.
MORTAR BED SLOPED 1/4" : 1'-0"
TOWARDS THE DRAIN
THINSET
THINSET
GALVANIZED EXPAND METAL
LATH OVER CLEAVAGE
MEMBRANE
EXTERIOR GRADE PLYWOOD OR
ORIENTED STRAND BOARD
FLOOR SUBSTRATE
COUPLING WITH
HOSE CLAMPS BY
OTHERS
PVC WASTE PIPE
BY OTHERS
WALL PARTITION
1"X6" NOMINAL BLOCKING
(2) 2"X6" OR 2"X8" NOMINAL
HEADER FRAME PARTITION WALL
1
4
"
[DUW(R)-T] 6" [151.71CM]
[DUW(R)-S] 6
3
8
" [162.57CM]
WOOD FRAME INSTALLATION