LITE, R1.
Notice This document contains DragonWave proprietary information. Use, disclosure, copying or distribution of any part of the information contained herein, beyond that for which it was originally furnished, requires the written permission of DragonWave Inc. The information in this document is subject to change without notice and relates only to the product defined in the introduction of this document.
Table of Contents 1 Preface .................................................................................................... 5 1.1 History of changes ........................................................................................................... 5 1.2 Scope of the document .................................................................................................... 5 1.3 Intended audience .................................................................................................
Preface 1 Preface 1.1 History of changes The history of changes is shown in the following table: TABLE 1. History of changes Revision Updates Update date 1 1st revision August, 2013 2 In Chapter 2, some warnings are added to meed the requirements. May, 2014 1.2 Scope of the document This document provides the guidance to install and commission the LITE system. INFO This document only concerns LITE system release 1.0 (LITE R1.0 in short) without specific statements in the context. 1.
Preface 6
Before installation 2 Before installation 2.1 Precautions The radiation emitted by the antenna is low-power radiation and does not exceed the safety regulations. If the radio is operated without antenna, the safety limit is exceeded near the waveguide openings. WARNING! THE INSTALLATION MUST ONLY BE PERFORMED BY A QUALIFIED TECHNICIAN. WARNING! RISK OF PERSONAL INJURY. THIS PRODUCT MAY NEED TO BE INSTALLED ON A HIGH-RISE STRUCTURE SUCH AS A TOWER OR MAST.
Before installation • When the equipment is installed in regions where the temperature falls below zero degree Celsius during the winter, ice can accumulate on the installation tower structure. Take precautions to avoid the breakage of antennas due to falling ice. Suitable protection can be achieved, by installing a metal grating above the antenna. 2.
Before installation • (Only needed when PoE+ function is required) 1 x Ethernet cable for LITE internal use (length: 0.12 m); • (Only needed when external antenna is used) 2 x pre-assembled antenna cable for sub-6 GHz with connectors (length options: 1 m, 2 m, 3 m, 4 m, 5 m); and • 1 set of mounting kit. FIGURE 2.
Before installation FIGURE 3. Step 1 1 4 3 2 x4 x4 x4 ELEVATION AXIS 2. Connect base bracket as shown. Connect item 5 to item 1 (mate the knurled surfaces) using item 6, 7, 8 and 9. Note that the bolt head shall be positioned in the socket of item 1. Using tightening torque of 24 N/m to the azimuth and elevation hardware. FIGURE 4.
Mounting Steps 3 Mounting Steps The equipment can be mounted in the following four options: • • • • Option 1: on the wall; Option 2: on the pole (1’ ~ 1.75’ diameter); Option 3: on the pole (1.75’ ~ 3’ diameter); or Option 4: on the pole (3’ ~ 4.55’ diameter). 3.1 Mounting on the wall Steps: 1. Install the M6 x 60 expansion bolt in the wall. FIGURE 5. Step 1 2. Attach the mounting kits to the wall by M6 x 60 expansion bolt. FIGURE 6. Step 2 3. Attach the mounting kits to the equipment.
Mounting Steps FIGURE 7. Step 3 4. Tighten the grounding cable in the equipment. FIGURE 8. Step 4 5. Install the grounding cable with the enclosed parts. FIGURE 9.
Mounting Steps 3.2 Mounting on the pole (1’ ~ 1.75’ diameter) Steps: 1. Attach the mounting kits to the equipment. Refer to Chapter 2 Before installation. 2. Pre-assemble the mounting bracket on the pole. FIGURE 10. Step 2 3. Tighten the nut with spanner. FIGURE 11. Step 3 4. Tighten the grounding cable in the equipment. 5. Install the grounding cable with the enclosed parts. 3.3 Mounting on the pole (1.75’ ~ 3’ diameter) Steps: 1. Attach the mounting kits to the equipment.
Mounting Steps FIGURE 12. Step 2 3. Tighten the nut with spanner. FIGURE 13. Step 3 4. Tighten the grounding cable in the equipment. 5. Install the grounding cable with the enclosed parts. 3.4 Mounting on the pole (3’ ~ 4.55’) Steps: 14 1. Attach the mounting kits to the equipment. Refer to Chapter 2 Before installation. 2. Pre-assemble the mounting bracket on the pole.
Mounting Steps FIGURE 14. Step 2 3. Tighten the nut with a flat blade screwdriver. FIGURE 15. Step 3 4. Tighten the grounding cable in the equipment. 5. Install the grounding cable with the enclosed parts.
Mounting Steps 16
Cabling 4 Cabling 4.1 Ethernet cable connection in the doghouse Ethernet cables are connected in two options: • P+E • PoE+ 4.1.1 P+E connection FIGURE 16. P+E connection Doghouse Cover P+E OUT (ETH 2) (Empty) (Empty) P+E IN (ETH 1) For Cascading To IDU or to LITE (when cascaded) Waterproof Plugs Cabling Channels Steps: 1. Unscrew the doghouse cover and open it. 2.
Cabling 3. (Optional) Unplug another waterproof plug and connect the Ethernet cable from P+E OUT (ETH 2) interface to a LITE for cascading through the cabling channel. 4. Close the doghouse. 4.1.2 PoE+ connection FIGURE 17. PoE+ connection Doghouse Cover P+E OUT (ETH 2) POE+ IN INTERNAL Internal Connection P+E IN (ETH 1) For Cascading Waterproof Plugs To IDU or to LITE (when cascaded) Cabling Channels Steps: 1. Unscrew the doghouse cover and open it. 2.
Cabling FIGURE 18.
Cabling 20