Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual Volume 4
ECFM CLI Command
Description
set ecfm port
Sets the port number that subsequent ecfm commands will apply to.
The default is "off".
Sequence:
set ecfm port [port number] [on | off] press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Note:
HC ODU only supports ecfm functions on port-1.
port number must be 1.
To verify the setting, run the command get ecfm port
get ecfm port press Enter
The system responds:
------------------------------
ecfm Status : Enabled
LLC Encapsulation : Disabled
MEPs Configured : 1
MIPs Configured : 1
set ecfm oui
Configure the Organization Unit Identifier (OUI).
Organizationally Unique Identifier (OUI) is a 24-bit number that is
purchased from the Institute of Electrical and Electronics Engineers.
Sequence:
set ecfm oui [xx:yy:zz] press Enter
The system responds:
< no response >
The system returns to the prompt ->.
To verify the setting, run the command get ecfm global information
set ecfm oui 00:07:58 press Enter
then
get ecfm global information press Enter
The system responds:
Configured OUI : 00:07:58
(……00:07:58 is the OUI belonging to DragonWave)
set ecfm error-log
This is Y.1731 command. Enables or disables the logging of
Continuity Check errors that occurred on the device in the Error Log
table and also sets the maximum size of the table.
The default is "off".
Sequence:
set ecfm error-log [on | off] [size <entries(1-4096)>] press Enter
The system responds:
< no response >
The system returns to the prompt ->