Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual – Volume 4
Required Action
Steps
set port eoam link-monitor
frame-sec-summary
threshold
Specify the threshold value for frame second summary. Threshold
error count for frame seconds summary should be lesser than window
size.
The default is 1.
Sequence:
set port eoam link-monitor frame-sec-summary threshold [port
<1-2>] [size<0 - 900>] press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam link-monitor frame-sec-summary threshold port 1 5
press Enter.
To verify the setting, run the command:
get port eoam local information press Enter
The system responds: (Example)
Eoam Frame Seconds Summary Event Configuration:
Port ErrFrameSec Summary Window ErrFrameSec Summary Threshold
(100 msec)
------- -------------------------- -----------------------------
P1 100 5
P2 100 1
……
set port eoam fault-
management mib-variable
count
Sets the maximum MIB variables that can be sent in one OAM variable
request PDU.
The default is 6.
Sequence:
set port eoam fault-management mib-variable count [port <1-2>]
<count(1-100)> press Enter
The system responds:
< no response >
The system returns to the prompt ->.