User's Manual
Ethernet Operation Administration and Maintenance (EOAM)
13
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual – Volume 4
Required Action
Steps
set port eoam link-monitor
frame-sec-summary window
Specifies the window size for frame second summary. Window size
should be greater than threshold count.
The default is 100.
Sequence:
set port eoam link-monitor frame-sec-summary window [port
<1-2>] [size<100 - 9000>] press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam link-monitor frame-sec-summary window port 1 400
press Enter.
To verify the setting, run the command:
get port eoam local information press Enter
The system responds: (Example)
Eoam Frame Seconds Summary Event Configuration:
Port ErrFrameSec Summary Window ErrFrameSec Summary Threshold
(100 msec)
------- -------------------------- -----------------------------
P1 400 1
P2 100 1
……
set port eoam link-monitor
threshold
Specify the threshold for link events for Ethernet OAM link monitoring.
Threshold count should be lesser than window size for frame-period
The default frame threshold is 1; the default frame-period threshold is
1.
Sequence:
set port eoam link-monitor threshold [port <1-2>] [frame |frame-
period] [<count(1234..)>] press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam link-monitor threshold port 1 frame 5 press Enter.
To verify the setting, run the command:
get port eoam local information press Enter
The system responds: (Example)
Eoam Frame Event Configuration:
Port Errored Frame Window Errored Frame Threshold
(100 msec)
------- -------------------- -----------------------
P1 100 5
P2 10 1
……