User's Manual

DragonWave Inc.
12
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual Volume 4
Required Action
Steps
set port eoam fault-
management link-monitor
action
Specifies the action for the link monitoring threshold crossing events
received from local.
The default is “none”.
Sequence:
set port eoam fault-management link-monitor action [port <1-2>]
[frame | frame-period | frame-sec-summary ] [none | warning]
press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam fault-management link-monitor action port 1
frame none press Enter
To verify the setting, run the command:
get port eoam fault-management config port 1 press Enter
The system responds: (Example)
Link Event Action
-------------------------------------------------------------------
Frame Frame Frame secs Critical Dying Link MaxVar
Port Period Summary Event Gasp Fault Req
------- ------- ------- ---------- -------- ------- ------- ------
P1 None warning warning warning warning warning 10
P2 warning warning warning warning warning warning 10
set port eoam link-monitor
window
Specifies the window size for link events for ethernet OAM link
monitoring. Frame-period window size should be greater than
threshold count.
The default frame window size is 10; the default frame-period window
size is 10000000.
Sequence:
set port eoam link-monitor window [port <1-2>] [frame <size(10
- 600)> | frame-period <size(1100000 - 89000000)> ]press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam link-monitor window port 1 frame 200 press Enter.
To verify the setting, run the command:
get port eoam local information press Enter
The system responds: (Example)
Eoam Frame Event Configuration:
Port Errored Frame Window Errored Frame Threshold
(100 msec)
------- -------------------- -----------------------
P1 200 1
P2 10 1
……