User's Manual
Ethernet Operation Administration and Maintenance (EOAM)
11
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual – Volume 4
Required Action
Steps
set port eoam link-monitor
default
Sets the link monitoring parameters threshold and window to the
default value.
Sequence:
set port eoam link-monitor default [port <1-2>] [frame | frame-
period | frame-sec-summary] [threshold | window] press Enter
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam link-monitor default port 1 frame threshold press
Enter
To verify the setting, run the command:
get port local information press Enter
The system responds: (Example)
Eoam Frame Period Event Configuration:
Port ErrFrame Period Window ErrFrame Period Threshold
------- ---------------------- -------------------------
P1 10000000 1
P2 10000000 1
Eoam Frame Event Configuration:
Port Errored Frame Window Errored Frame Threshold
(100 msec)
------- -------------------- -----------------------
P1 10 1
P2 10 1
Eoam Frame Seconds Summary Event Configuration:
Port ErrFrameSec Summary Window ErrFrameSec Summary Threshold
(100 msec)
------- -------------------------- -----------------------------
P1 100 1
P2 100 1