User's Manual

Ethernet Operation Administration and Maintenance (EOAM)
9
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual Volume 4
Required Action
Steps
set port eoam fault-
management remote-
loopback
Start Eoam loopback test with the specified packet number, packet
size, test pattern, and wait time.
Sequence:
set port eoam fault-management remote-loopback [port <1-2>]
[test] [count <no of packets(1-1000)>] [packet <size(64-1500)>]
[pattern <hex_string(8)>] [wait-time <integer(1-10)>] press Enter
Where
port identifies a port number.
Test triggers loopback test
count identifies the number of loopback test packets.
packet size identifies the packet’s size. The range is from 64 to 1500.
pattern identifies the pattern string to transmit.
wait-time identifies the wait time (second) to receive the loopback
packets.
The system responds:
< no response >
The system returns to the prompt ->.
Example:
set port eoam fault-management remote-loopback port 1 test
count 20 packet 800 pattern 5050 wait-time 5 press Enter
The system responds:
Transmitting....
OAM Remote Loopback Test P1: 20 transmitted, 20 received