User's Manual

Installation Requirements
17
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual Volume 1
Mounting systems for the indoor units include a 19” rack mounting adapter, which accommodates up to
two units within a 1U rack space, and wall mount brackets, allowing a single unit to be wall, or shelf,
mounted as required (screw slots will accommodate 6mm (1/4”) diameter screws on 7.2 centres,
horizontally).
Figure 4-3 Two Indoor Units in Rack Mount Adapter
Figure 4-4 Indoor Unit with Wall Mount Brackets
Rack/cabinet in which Indoor units are installed must only be used for the
purposes of housing lightning suppression equipment.
Rack/cabinet must be equipped, grounded and bonded for lightning suppression
purposes.
Rack/cabinet must meet all local electrical and safety codes
Rack/cabinet must be certified by a qualified safety/lightning engineer.
DO NOT connect the grounding lug to AC power supply wiring ground!
DO NOT mix AC power supply option with site-supplied 48 VDC!
DO NOT connect the network to the RJ45 connectors marked
“TO HORIZON UNPROTECTED”. Damage to switches or routers may result
Wall mounting
brackets are
removable