User's Manual

DragonWave Inc.
84
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual Volume 2
Required Action
Steps
Configure rls link control
[on/off]
Determines whether RLS link control performs automatic recovery or
requires manual recovery of the Ethernet port. RLS provides the
ability to shut down the Horizon Compact Plus Ethernet ports (Port 1
on both endpoints) during system outages. The user can manually
recover the Ethernet ports through the use of the "set rls link enable
on" command.
The default is "off".
Sequence:
set rls link control [on/off] press Enter
The system responds:
RLS link control is set to [on/off]
Where
On means the user must manually recover the Ethernet port
through the use of the "set rls link enable on" command.
Off means the Horizon Compact Plus system will automatically
recover the Ethernet port.
View rls link enable
Displays the state of the Rapid Link Shutdown (RLS) link enable
feature. RLS provides the ability to shut down the Horizon Compact
Plus Ethernet ports (Port 1 on both endpoints) during system
outages.
The default is "off".
Sequence:
get rls link enable press Enter
The system responds:
RLS link enable is set to [on/off]
Where
On means to re-enable the Ethernet port on the modem
Off means the Ethernet port is not re-enabled.
Configure rls link enable
[on/off]
Manually enables or disables the Horizon Compact Plus Ethernet
link. This feature requires the rls link control feature to be "on".
The default is "off".
Sequence:
set rls link enable [on/off] press Enter
The system responds:
RLS link enable is set to [on/off]
Where
On means to re-enable the Ethernet port on the modem
Off means the Ethernet port is not re-enabled.