User's Manual

DragonWave Inc.
74
Horizon Compact Plus Release 1.0.1 Wireless Ethernet Product User Manual Volume 2
Steps
Sets the SNR level below which a threshold alarm will be raised.
Sequence:
set snr threshold <snr value> press Enter
Where <snr value> is in dB and between 0 and 30
The system responds:
SNR threshold set to : n
Where n is the new SNR threshold setting
Displays the current settings for the Bandwidth Utilization Threshold
Alarm.
Sequence:
get bandwidth utilization threshold press Enter
The system responds:
Bandwidth utilization threshold set to : <value> % Bandwidth
utilization timelimit set to : <timelimit> secs.
Where
<value> is the current bandwidth utilization value expressed in
percentage
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds
Sets the values for the Threshold Alarm for the Bit Error Rate (BER) as
calculated by the Horizon Compact Plus modem. Once the BER
Value Threshold is reached and continues to remain between the
Threshold value and the hysteresis value, then an alarm is raised.
Once the value drops below the hysteresis value then the alarm is
cleared.
Sequence:
set bandwidth utilization threshold <value> <timelimit> press
Enter
Where
<value> is the current bandwidth utilization value expressed in
percentage
<timelimit> is the desired time limit that the condition must occur
before the alarm is raised. Timelimit is in integers, given in number
of seconds. Default value is 10 seconds
The system responds:
Bandwidth utilization threshold set to : <value> % Bandwidth
utilization timelimit set to : <timelimit> secs.