13.0 Threshold Alarms
Horizon Compact Plus provides Threshold Alarms to assist in managing the performance of the system.
Threshold alarms are available for the following parameters, showing default setttings:
RSL (Receive Signal Level) -70 dB for 10 seconds
Bandwidth Utilization 100% for 10 seconds
Dropped Frames (for all data queues) 100% for 10 seconds
In addition to the total Dropped Frames threshold, each of the eight QoS queues can be
allocated an individual threshold alarm
Queue Utilization (for all data queues) 100% for 10 seconds
Each queue can be allocated an individual queue utilization alarm
SNR (Signal To Noise) 0 dB*
Most Threshold Alarms have two associated alarm parameters:
1. Threshold value
2. A time limit over which the Threshold value must be exceeded before the alarm is
reported.
The combination of the value and the time limit is user defined. The proper combination of the two
parameters will prevent false alarms from occurring.
* For the SNR parameter, only the threshold level can be set, the time limit, or hysteresis, being a preset
value.
Procedure 13-1
Configure Threshold Alarms
Perform this procedure to configure the Threshold Alarms for the Horizon Compact Plus system. Each
Threshold Alarm may be configured independently of each other, and each end of the link may be
configured for different values.
Note: To perform this procedure, you must have NOC user rights.
Required Action
Steps
login
Log in as a NOC user.