User's Manual
DragonWave Inc. 20
AirPair 100 UL 24 GHz Product Manual
Required Action Steps
get available frequency Displays the frequency bank. This will show the frequencies for the
direction programmed using the set frequency bank command. If the
frequency bank was selected to GO, then the GO bank of frequencies is
displayed, and similarly the RETURN bank of frequencies is displayed if
the RETURN frequency bank was selected. .
Sequence:
get available frequency press Enter
The system responds:
(“go” frequencies shown. “return” frequencies will be displayed if the
return bank was programmed).
go Frequencies
Index TX IF RX IF TX RF RX RF
UNL1 670 2000 24080 24150
UNL2 660 1990 24090 24160
UNL3 650 1980 24100 24170
UNL4 640 1970 24110 24180
UNL5 630 1960 24120 24190
UNL6 620 1950 24130 24200
UNL7 610 1940 24140 24210
UNL8 600 1930 24150 24220
Note: All Frequencies in MHz.
set programmed frequency
[frequency index]
Sets the programmed frequency.
Sequence:
set programmed frequency [frequency index] press Enter
The system responds: ( example uses set programmed frequency
UNL1)
Index TX IF RX IF TX RF RX RF
UNL1 670 2000 24080 2415
Note: All Frequencies in MHz.
get programmed frequency Displays the programmed frequency.
Sequence:
get programmed frequency press Enter
The system responds: ( example uses set programmed frequency
UNL1)
Index TX IF RX IF TX RF RX RF
UNL1 670 2000 24080 24150