User Manual
    www.dragino.com 
LTC2 LoRaWAN Temperature Transmitter      27  /  32 
Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:   
https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/   
Step 2: Open it and choose   
➢  Product Model 
➢  Uplink Interval   
➢  Working Mode 
And the Life expectation in difference case will be shown on the right.   
5.  Firmware Change Log and Upload Firmware 
User can use ST-Link v2 to upgrade firmware into LTC2 for bug fix or new features. The hardware 
connection for upgrade firmware is as below:   
Connection: 
✓  ST-LINK v2 GND <--> LTC2 GND 
✓  ST-LINK v2 RESET <--> LTC2 NRST 
✓  ST-LINK v2 SWCLK <--> LTC2 SWCLK 
✓  ST-LINK v2 SWDIO <--> LTC2 SWDIO 
✓  LTC2 power must be on.     
Firmware Location and Change Log: 
http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LTC2/Firmware/  