User manual

Operation
6 Operation
Pos: 72 /806-IHSE/Be trieb/Laden von DDC-Infor matio .doc @ 43130 @ 2 @ 1
6.1 Download of DDC Information
nen/477-xx @ 5\mod_127 8937455136_6
By default, data from the internal DDC list is reported to the source
(computer, CPU). If these are not optimal settings for the display device,
the DDC information of the console monitor can be downloaded and
stored internally. The devices have to be configured accordingly (see
Chapter 5.2, Page 48).
On all KVM Extenders with USB-HID support, the user can load the DDC
information of the console monitor via keyboard command under operating
conditions.
1. Enter Command Mode with the 'Hot Key' (see Chapter
5.2, Page 48).
2. Press the <a> key to download the DDC information of the console
monitor.
T
he screen will go black for a short time.
At the same time Comma
nd Mode is closed and the keyboard LEDs
return to previous status.
3. Restart the corresponding source (computer, CPU).
T
he video mode has been readjusted. Screen quality should be
optimal. The CPU should now show the console monitor as the
current screen, together with the available video resolutions.
T
he DDC information of the console monitor was loaded once.
Reloading is possible by repeating the operation.
Pos: 73 /806-IHSE/Be trieb/Parallelbe trieb/474-xx_Par 9\mod_1373962269987_6.doc @ 77387 @ 2 @ 1
6.2 Shared Operation of redundant CPU Units
allelbedienung r edundanter CPU Units @
CPU Units with a redundant connector for interconnect cables offer the
possibility for a competing control by two connected CON Units.
Taking over control is performed using a keyboard and/or mouse. The
release timer function determines the release time of the input devices at
one of the CON Units after that control can be taken over from the second
CON Unit.
2014-11-11 55