User manual
Configuration
Shared Operation
Parameter Function
KBDCON
Activate Keyboard Connect (only with redundant
CPU Units)
MOUCON
Activate Mouse Connect (only with redundant
CPU Units)
RELEASETIME=n
Release timer n = 0...9 seconds for Mouse and
Keyboard Connect, without parameter =
10 seconds
General Settings
Parameter Function
DISPLAY2
Show video channel 2 per default after
switching on the respective Dual-Head unit
(482 series only)
5.5.2 Parameters for CON Units
You can write the following parameters into the configuration file of a CON
Unit.
Output Settings
Parameter Function
1080p50Hz Always display 50 Hz when using 1920x1080
DISEXTOSD Deactivate extender OSD
ENAFRAME
Show orange colored frame when losing
extender connection
ENAHOLDPIC
Show last transmitted picture highlighted by an
orange colored frame when losing connection
ENADDCTX
Activate DDC transmission by unplugging and
connecting the monitor back to the CON Unit
CENTERMODE
Simulate the native resolution of Dual-Link
monitors by an additional black frame in order to
enable Instant Switching (482 series only).
PARAM=V
Simultaneous output of DVI-D and VGA signal
(R474-BVHx and R474-BVHxR only)
2014-11-11 53