16-66 ELECTRICAL SYSTEM
Meter
Drive Belt Failure Mode Memory Clearing
Procedure
A flashing BELT check indicator LED (Light Emitting
Diode) l ight means that the drive belt failure detection
system has activated. The belt check indicator light will
illuminate and stay on when activated b y the 100 hour belt
check s ystem.
NOTE
Follow the instruction on page 2-25 of this Service Man-
ual to complete the necessary inspections.
After completing the inspections, follow these instruc-
tions to clear the system memory and turn off the light.
Turn off the ignition switch.
Remove the seat (see Seat Removal in the Frame chap-
ter).
Disconnect both sets of 4 pin connectors [A] in the elec-
trical parts case.
Reconnect these 4 pin connectors to their opposite gray
to black and black to gray as shown.
Turn on the ignition switch.
Observe the belt check indicator light [A].
It should be flashing quickly.
Disconnect the belt switch a t the 2 pin connectors [A]
above the torque converter cover.
Observe the belt check indicator light.
It should be flashing slowly.
Let it flash for at least five seconds.
NOTE
More than five seconds is OK.
While observing the belt check indicator light, turn off the
ignition switch.