Service manual

Table Of Contents
16-64 ELECTRICAL SYSTEM
Meter
Check 10: Neutral Indicator Light Check
Connect the wires in the same manner as Check 1.
Connect terminal [8] to the battery (–) terminal.
The neutral indicator light (LED) [A] should go on.
If the LED light does not go on, replace the meter unit.
Check 11: Reverse Indicator Light Check
Connect the wires in the same manner as Check 1.
Connect terminal [7] to the battery (–) terminal.
The reverse indicator light (LED) [A] should go on.
If the LED light does not go on, replace the meter unit.
Check 12: Meter Illumination Check
Connect the wires in the same manner as Check 1.
Connect terminal [6] to battery (+) terminal.