Service manual

Table Of Contents
ELECTRICAL SYSTEM 16-33
Charging System
Regulator/Rectifier Inspection
Remove:
Regulator/Rectifier (see Regulator/Rectifier Removal)
Set the hand tester to the × 1 k range and make the
measurements shown in the table.
Special Tool - Hand Tester: 57001-1394
Connect the hand tester to the regulator rectifier.
If the tester readings are not as specified, replace the
regulator/rectifier.
CAUTION
Use only Kawasaki Hand Tester 57001-1394 for this
test. A tester other than the Kawasaki Hand Tester
may show different readings.
If a megger or a meter with a large capacity battery
is used, the regulator/rectifier will be damaged.
Regulator/Rectifier Resistance (Unit: k)
Tester (+) Lead Connection
Term in al A B
C
D E
A
B 2 26
C
2 26
D 2 26
(–)*
E 2 50 2 26 2 26 2 26
()*: Tester () Lead Connection
Charging System Circuit
1. Ignition Switch
2. Fuse Box
3. Main Fuse 30 A
4. Regulator/rectifier
5. Engine Ground Terminal
6. Battery 12 V 12 Ah
7. Alternator
8. Load