Radiator
Install the cap [A] on a cooling system pressure tester [B].
NOTE
Wet the cap sealing surfaces with water or coolant to
prevent pressure leakage.
Watching the pressure gauge, slowly pump the pressure
tester to build up the pressure. The relief valve opens,
indicated by the gauge hand flicks downward.
The relief valve must open within the relief pressure range
in the table below and the gauge hand must remain within
the specified range at least 6 second.
Radiator Cap Relief Pressure
Standard: 93 123 kPa (0.95 1.25 kgf/cm², 14 18
psi)
If the cap cannot hold the specified pressure, or if it holds