Recharging 
Jaguar robot uses high performance LiPo batteries. Extreme caution is needed when dealing with this type of 
battery, explosion and damage could occur. Please read the Charge Station manual first and follow all the safety 
rules before proceeding further. 
1) Turn off the robot 
2) Loose the screws of Battery Box, disconnect the 2-Pin Tamiya connector 
and take the Battery Box out. 
3) Power on the Charge Station. Use 
to make sure "LiPo BALANCE" is 
displayed on the LCD screen. If not, use "Type/Stop" button to change 
battery type to "LiPo Battery" and press 
 to set charging mode to “LiPo 
BALANCE” . 
4) You can use 
 +    /   +  buttons to change the charge 
current, DO NOT exceed the 2A charging current and do not modify the battery voltage. It should be "22.2V 
(6S)" for Jaguar robot. 
5) Connect the charging 7-Pin & 4-pin connectors to charger 
6) Press 
 button for few seconds, the charge station will check the battery and display what the reading is. It 
should be same as your settings above. 
7) If everything is right, you can press 
 button again to start charging. 
8) Press 
 to switch the display to show the battery status. The display 
should show each battery reading as below image. 
* Note: If any battery reading is missing, please turn off the charging station and turn the Power switch to “OFF”, 
and check the 7-pin connector, make sure it is connect well. 
9) Keep the charger away from children and pet at all time! Never leave the charger unsupervised when it 
is connected to its power supply. For more detail about charger station operation, warning and error message, 
maintenance and safety message, please refer to “Intelligent Digital Balance Charger Operating Manual”. 