Installation manual
Model PC UVS2000
4
ROUTINE MAINTENANCE
It is important that any water treatment system be properly maintained to ensure consistent water
quality. The information provided on this page is of a general nature. See Cleaning, Disinfecting, and
Routine Maintenance Procedure on Page 10 for detailed information. Refer to Mounting Bracket and System
Plumbing Installation Instructions on Page 5, and System Assembly and Activation Procedures for detailed
information to install your Pure & Clear system.
CLEANING
The inside of the system and the quartz sleeve
parts) with soap and rinse them thoroughly with
clean potable water. Dry the inside of the quartz
sleeve thoroughly before re-assembling system.
NOTE: Presence of iron or general poor water
quality will require frequent inspection
and cleaning.
“O” Rings: Lubricate each “O” ring with a silicone
based “O” ring lubricant to ensure a proper seal.
NOTE: UV lamp should remain on at all times
during use because: repeated starting of
UV lamp shortens lamp life, and UV lamp
requires a warm up period of 1-2 minutes.
FILTER REPLACEMENT
Filters will normally last approximately four to six
months. Filter life will vary due to water conditions.
are specially designed to work in the ultraviolet
disinfection process. Use of non-Pure & Clear
CAUTION:
avoid breaking the quartz sleeve.
UV Lamp Replacement: Lamps must be changed
every twelve months. While UV lamps rarely burn
out, they do lose their disinfection power. Use only
Pure & Clear
designed for the Pure & Clear UV Water Filter system
to deliver high quality drinking water.
SPECIFICATIONS
Inlet/
Outlet
3/4” NPT†
Shipping Weight
lbs. (kg)
Dimensions
Inches (Centimeters)
Height x Width x Depth
Flow Rate
Gallons Per Minute
Liters Per Minute
Lamp Type &
Power Used
Watts
16.0 lbs (7.3 kg) 25.0” (63.5 cm) x 5.5” (14.0 cm) x 5.5” (14.0cm) 10 gpm (38 L/min)
UV Lamp #20
22 Watts
† Female thread as recognized by United States National Pipe Thread
Pure & Clear UV Well Water Filter
9
SERVICE REQUIREMENTS AND RECOMMENDED SERVICE INTERVALS
Service Requirements Recommended Service Intervals
To ensure the system operates at its optimum level,
certain routine maintenance must be performed.
Frequency of maintenance performance will
depend on source water quality and level of
system usage.
CLEAN:
DISINFECT: At least once a year
UV Lamp: Change Annually
Quartz Sleeve and Channeling Sleeve: Clean when
be cleaned by non-abrasive methods.
Filters: Normal life 406 months. Filter life will vary
must be changed.
PARTS ILLUSTRATION & PARTS LIST
Exploded Schematic
Pure & Clear UV Well Water Filter
Item Description
1 Housing, UV, Sump, “O” Ring, Head UV
2 “O” Ring, Sump #10/20
3 Sleeve, Channeling S/S, #20
4 Gasket, Sleeve
6 Mounting Bracket, 1 Sump
7 Switch, Safety
8 Indicator, LED
9 Fuse, 1A Type 3AG
10 Module, UV control #20
11 Screw, 6/32 x 3/8”
12 Screw, #10 x 3/4”
13 Screw, ¼” x 1-1/2”
14 Washer, #14 Nylon
15 “O” Ring, Quartz Sleeve, Standard (2)
16 Lamp UV #20
17 Sleeve Quartz #20, with “O” rings
18 Rod, Safety Plunger
19 Spacer, Bushing #10/20
FIGURE 2
4 Model PC UVS2000 Model PC UVS2000 9