Operation Manual

38
If the ventilation unit is lying on the fixed segment, the
assembly holes in the holding bracket of the ventilation
unit have to align with those in the upper outside walls
of the fixed segments.
Fig. 25
Fasten the exhaust air unit with 2 screws (M10) per
holding bracket and 2 nuts (M10) to the fixed segments
(Fig. 25).
Fasten the hose with a hose clamp to the flange.
The exhaust air fitting for the exhaust air hose is pre-
assembled (Fig. 26).
(required hose = nominal diameter 400)
Fig. 26
Remove the loudspeaker on the inside of the of the
center column, in order to access the terminals for the
cable plug (Fig. 28).
After the mechanical connection of the fixed segments
to each other and to the air exhaust unit, the electrical
has to take place now.
Lay all connecting cables along the upper side of the
fixed segments to the center column.
Then these cables can be guided through the upper
opening in the center column (Fig. 27).
Assembly of the electrical connections
Fig. 27
Fig. 28
english