Pivot the lamp frame into the fixed segment and fasten
with the provided Phillips head screw (Fig.23).
Make the electric connection for the venting (lower
terminal) in the inside area (Fig.22).
Then fasten the wires to the terminal.
Now pivot the lamp frame into the open position and
plan the electric connection for the UV-lamps (upper
terminals) in the inside area (Fig.21).
Fasten the wires to the terminals.
Fig. 21
Fig. 22
Fig. 23
Before you slide the ventilation unit on the front side onto
the fixed segments you have to make sure that all
electrical connection cables of the fixed segments are
hanging over the upper edge of the rear wall to the out-
side (Fig. 24).
Assembly of the exhaust air unit
Fig. 24