Operation Manual
35
The center column with the control is mounted into the
space between the two inner fixed segments (high
pressure segments).
Please note:
All electric connections of the radiation segments, as
well as the exhaust air have to have taken place before
fastening the center column to the fixed segments.
Only then can the front plate be attached to the control
unit and the adjoining segments connected.
Position the center column between the fixed segments
(Fig 14).
Assembly of the center column
Connect these sideways with both segments (fig 15).
Use socket head screws M6 (DIN 912, M6 x 20) from
the enclosed package.
Fig.14
Fig.15
Center
column
Important Tip:
After all fixed elements as well as the center column
have been assembled, they have to be leveled again
with a level!
After the HDB-fixed segments have been fastened to
the floor plate, the filter disk frame can be assembled
again.
Position the door unit in such a way that the bearing
bolt is located at the opening of the door unit. At first
place the door unit into the lower bearing bolt (Fig. 16).
Installation of the HDB-elements
Fig. 16
Filter disks frame
bearing bolt
english